Abstract

Eddy current testing (ECT) probe consisted of spin‐valve giant magneto‐resistance (SV‐GMR) sensor and meander type exciter coil applied to printed circuited board (PCB) conductor dimension and alignment inspection is proposed in this paper. High‐frequency excitation up to 18 MHz is allowed to inspect the thin PCB conductor, less than 10 μm. The proposed ECT probe characteristics and configuration were presented. The inspection results were shown that the proposed ECT probe will provide an accurate inspection.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.