Abstract

This paper deals with sensor signal noise of eddy current testing (ECT) probe generated in helical heating tube in the fast breeder reactor MONJU. ECT probe is used for inspection of thickness of heating tube. The heating tube is composed of helical tube and straight tube because of advantage of thermal efficiency and compact size. However, the vibration of probe having no experience in usual straight heating tubes is generated. The vibration causes the noise and the decrease of sensor sensitivity of ECT probe. The experiment was performed by using a mock-up, and the noise characteristics of ECT sensor signal mounted in ECT probe were examined. The experimental result showed that the sensor signal noise in inserting ECT probe was higher than that in return process and the vibration in insert process had a certain outstanding frequency. It was effective for the countermeasure of sensor signal noise to attach the long and flexible guide probe to the top of ECT probe.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.