Abstract

Background and AimsInflammatory bowel disease (IBD) is a global disease that is evolving with increasing incidence. However, there are few works on computationally assisted diagnosis of inflammatory bowel disease based on pathological images. Therefore, based on the UK Ulcerative Colitis Guidelines, our study established a histological grading system for inflammatory activity in ulcerative colitis (UC). MethodsWe proposed an efficient deep-learning (DL) method for grading inflammatory activity in whole-slide images (WSIs) of UC pathology. Our model was constructed using 603 UC WSIs from Nanjing Drum Tower Hospital, the affiliated hospital of Nanjing University Medical School for model train set and internal test set. We collected 212 UC WSIs from Zhujiang Hospital of Southern Medical University as an external test set. Initially, the pre-trained ResNet50 model on the ImageNet dataset was employed to extract image patch features from UC patients. Subsequently, a multi-instance learning (MIL) approach with embedded self-attention was utilized to aggregate tissue image patch features, representing the entire WSI. Finally, the model was trained based on the aggregated features and WSI annotations provided by pathology experts to predict the level of inflammatory activity in UC WSIs. ResultsIn the task of distinguishing the presence or absence of inflammatory activity, the Area Under Curve (AUC) value in the internal test set is 0.863 (95% confidence interval [CI] 0.829, 0.898), with a sensitivity of 0.913 (95% [CI] 0.866, 0.961), and specificity of 0.816 (95% [CI] 0.771, 0.861). The AUC in the external test set is 0.947 (95% confidence interval [CI] 0.939, 0.955), with a sensitivity of 0.889 (905% [CI] 0.837, 0.940), and specificity of 0.858 (95% [CI] 0.777, 0.939). For distinguishing different levels of inflammatory activity in UC, the average Macro-AUC in the internal test set and the external test set are 0.827 (95% [CI] 0.803, 0.850) and 0.908 (95% [CI] 0.882, 0.935). the average Micro-AUC in the internal test set and the external test set are 0.816 (95% [CI] 0.792, 0.840) and 0.898 (95% [CI] 0.869, 0.926). ConclusionsComparative analysis with diagnoses made by clinicians at different expertise levels revealed that the algorithm reached a proficiency comparable to the pathologist with 5 years of experience. Furthermore, our algorithm performed superior to other MIL algorithms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.