Abstract

BackgroundMetal alloys containing contact sensitizers (nickel, palladium, titanium) are extensively used in medical devices, in particular dentistry and orthopaedic surgery. The skin patch test is used to test for metal allergy.ObjectiveTo determine whether metal salts, when applied to freshly excised skin at patch test–relevant concentrations and using a method which mimics skin patch testing, cause in changes in the epidermis and dermis.MethodsTissue histology, apoptosis, metabolic activity, and inflammatory cytokine release were determined for two nickel salts, two palladium salts, and four titanium salts.ResultsPatch test–relevant concentrations of all metal salts caused localized cytotoxicity. This was observed as epidermis separation at the basement membrane zone, formation of vacuoles, apoptotic nuclei, decreased metabolic activity, and (pro)inflammatory cytokine release. Nickel(II) sulfate hexahydrate, nickel(II) chloride hexahydrate, titanium(IV) bis(ammonium lactato)dihydroxide, and calcium titanate were highly cytotoxic. Palladium(II) chloride, sodium tetrachloropalladate(II), titanium(IV) isopropoxide, and titanium(IV) dioxide showed mild cytotoxicity.ConclusionThe patch test in itself may be damaging to the skin of the patient being tested. These results need further verification with biopsies obtained during clinical patch testing. The future challenge is to remain above the elicitation threshold at noncytotoxic metal concentrations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call