Abstract

Time Projection Chamber (TPC) is one of the main tracking systems for many current and future collider experiments at RHIC and LHC. It has a capability to measure the space points of charged tracks for good momentum resolution as well as the energy loss (dE/dx) for particle identification with good energy resolution. Both of these features depend strongly on the amount of space charge in the TPC gas volume, mainly due to the ions from the amplification stage. An active gating grid has been used thus far to gate the electrons and ions by switching the polarities of the grid wires. Therefore, active gating does introduce a limitation for data taking rates in high luminosity collisions. In this work we propose several options of a passive gating, where a significant reduction of Ion Back Flow (IBF) is possible in a high luminosity environment without any dead time issues due to gating operation. Particularly, the application of a TPC passive gating for the sPHENIX experiment at RHIC is presented, which is currently under development.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.