Experimental and numerical studies were conducted to investigate passive control of a forward-curved centrifugal fan noise by employing the open-cell metal foam (OCMF). The results indicated that a reduction of about 5dB in overall A-weighted sound pressure level (OASPL) was successfully achieved with a decline of about 200Pa in total pressure rise (TPR). For the OCMF investigated in the present paper with the pores per inch (PPI) of 20 and the porosity of 97%, the noise control mechanism was to suppress the source strength of tonal noise generated from the periodic impeller–tongue interaction rather than to absorb the broadband acoustic energy. The decline of the aerodynamic performance was mainly caused by reducing the work capacity of the impeller rather than caused by flow loss owing to the flow resistance of the OCMF. An improved design of the OCMF was suggested to achieve more reduction in noise level with less decline of aerodynamic performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.