Abstract

The present study investigates particle depositions on convergent nozzle walls of (HVOF) spray guns, a process that reduces nozzle lifetime and degrades operation stability and reliability. We perform three-dimensional, two-way coupled simulations of reactive particle-laden compressible flow through a typical thermal spray gun nozzle. We determine critical radial particle velocities at which particles deposit on the wall. We characterize critical velocities concerning particle trajectories, particle diameter, and downstream location of particles deviating from the nozzle center. The critical velocity decreases with particle diameter and increases with the downstream location at which particles deviate from the nozzle center. We exclude the possibility that single particle–particle collision events create sufficient radial particle momentum for deposition. We use the gained insights to propose mitigating measures against particle depositions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.