Abstract

The partial insulation winding was examined to ameliorate the slow charge–dischargeshown by coils wound without insulation. Single pancake coils of GdBCO coated conductorwere wound without insulation, with kapton tape every five turns, and with the full use ofkapton tape. They were characterized by charge–discharge, sudden discharge, andover-current testing. The improved charging and discharging and high thermal andelectrical stabilities of the partially insulated coil demonstrate its potential for use in HTSpower applications.