Abstract
This paper presents two improved triple parity placement schemes, the HDD1 (Horizontal and Dual Diagonal) scheme and the HDD2 scheme, to enhance the reliability of a disk array system. Both the schemes can tolerate up to three column disk failures by using three types of parity information (horizontal, diagonal, and anti-diagonal parities) in a disk array. HDD1 scheme can decrease the frequency of bottlenecks because its horizontal and anti-diagonal parities are uniformly distributed over a disk array, with its diagonal parities placed in dedicated column disks. HDD2 scheme possesses one more column disks than HDD1 to store the horizontal parities and an additional diagonal parity; its anti-diagonal and diagonal parities are placed in the same way as in HDD1 scheme, only with a minor difference. The encoding and decoding algorithms of the two schemes are rather simple and straightforward, some steps of its procedure can even be executed in parallel, which makes the disk failure recovery faster.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.