Abstract
Abstract In order to achieve high reliability in disk array systems, two new schemes using dual parity placement, called DH1 (diagonal–horizontal) and DH2 schemes, are presented. Both DH schemes can tolerate up to two disk failures by using two types of parity information placed in the diagonal and the horizontal directions, respectively, in a matrix of disk partitions. DH1 scheme can reduce the occurrences of the bottleneck problem significantly because the parity blocks are evenly distributed throughout the disk array. DH2 scheme uses one more disk than DH1 scheme in order to store the horizontal parities, while the diagonal parities are placed in the same way as in DH1 scheme with a minor change. Even though both DH schemes use almost optimal disk space for storing the redundant information, the encoding algorithms for them are quite simple and efficient. Moreover, both DH schemes can recover rapidly from any two disk failures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.