Abstract

IntroductionThe parallel grafting technique (PGT) is a valuable alternative to prefabricated branched or fenestrated endovascular aortic repair. An often overlooked advantage of PGT is its unique adaptability to different anatomical challenges that might appear intra-operatively.ReportA 72 year old male patient presented with a 60 mm thoracic aneurysm, 59 mm juxtarenal abdominal aortic aneurysm, and 32 mm common iliac aneurysm (CIAA). Thoracic endovascular aortic repair plus endovascular aortic repair with bilateral renal artery chimneys and CIAA exclusion applying the sandwich technique was proposed. Because of unfavourable angulation it was not possible to achieve selective left renal catheterisation via axillary access. Changing to a femoral approach allowed successful retrograde catheterisation. The procedure ended with a chimney for the right renal artery and a periscope for the left renal artery. The final angiogram showed no endoleaks and renal and hypogastric patency. The patient was discharged three days after the procedure and remains under ultrasound surveillance after 40 months because of a small type two endoleak.ConclusionWhen using a prefabricated branched device, the possibility of selectively catheterising a visceral branch often has no straightforward solution. However, parallel grafting is an extremely flexible technique, which was of paramount importance for the surgical outcome of the present case.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call