Abstract

A physical model is presented that describes mechanisms for operating-equipment junction-to-ambient thermal resistance in excess of a typical component manufacturer's data-sheet value by as much as a factor of four under constant cooling conditions. The model accounts for the discrepancy between system thermal performance of a package and data-sheet thermal resistance value which are not accompanied by qualifying data in the form of junction-to-header thermal resistance, board temperature rise over ambient, convection coefficient, mounting sensitivity, and power dissipation. The eight constants used to predict inherent increases in package thermal resistance when going from the data-sheet-specified operating conditions to the excess-value conditions are described. These constants and procedures for obtaining them are given for dual in-line packages (DIPs), pin-grid arrays (PGAs), small-outline transistors (SOTs), and plastic leaded chip carriers (PLCCs). >

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.