Abstract

Background: Amplification techniques such as PCR are becoming increasingly popular in the field of diagnosis of human cytomegalovirus (HCMV) also, thus substituting conventional techniques like the time consuming HCMV antigen or cell culture assays. Current PCR protocols however, are labor intensive, and moreover, the need for extensive postamplification manipulations increases the risk of false positive results due to contamination with amplified products. Objectives: to overcome these shortcomings, the new ultrarapid and semi-automated real-time LightCycler PCR-system (LC-PCR), which combines amplification and detection in a closed capillary system, was tested for its suitability in diagnosis of HCMV in urines. Study design: 73 urine samples from 64 newborns and infants suspected of having congenitally or postnatally acquired HCMV were tested with the LC-PCR and results were compared with those obtained in parallel with a conventional PCR-ELISA and the rapid shell vial assay for detection of HCMV early antigen (EA-assay). Results: with these methods, 31 newborns/infants were found to be infected with HCMV. HCMV DNA was detected in 39 urines while the EA-assay was positive in 33 urines. All the EA positive samples were also positive for HCMV DNA. In the urines of the remaining 33 newborns (34 urine samples) neither HCMV DNA nor EA were detectable. The overall agreement of the two PCR tests was 100% while a 92% agreement was obtained between the PCR and the EA-assays. As the sensitivity of the three tests turned out to be quite similiar, the discrepancy observed in the positive rate between PCR and EA-assay is due to other factors which will be discussed in detail. However, while LC-PCR takes only about 2 h from sample preparation to result generation, the EA-assay, such as the conventional PCR-ELISA, needs 24–48 h. Furthermore, due to its capability to perform cycle-by-cycle monitoring, the LC instrument enables semi-quantitative analysis of HCMV viral-load. Conclusions: LC-PCR is a suitable new tool for routine analysis of HCMV in the urines of newborns and infants. Compared to the conventional PCR-ELISA a considerable increase in test rapidity and reliability is achieved without the need to sacrifice sensitivity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.