Charge induced in 6H-SiC nMOS capacitors by 15 MeV oxygen ion microbeams was measured using Transient Ion Beam Induced Current (TIBIC) before and after gamma-ray irradiations. The peak amplitude of TIBIC signals decreases and the fall time increases with increasing number of incident ions. The decrease in the TIBIC peak eventually saturated. The TIBIC signal can be refreshed to its original shape by applying a positive bias of + 1V to gate oxide. Small decrease in both the peak amplitude of TIBIC signal and collected charge was observed due to gamma-ray irradiation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.