Abstract
The study explored the effect of ambient oxygen on mammalian cell survival after exposure to 10 ns duration, high voltage electrical pulses (nsEP, 80-90 or 120-130 kV/cm; 200-400 pulses per exposure). Cell samples were equilibrated with pure nitrogen, atmospheric air, or pure oxygen prior to the nsEP treatment and were returned to the incubator (air + 5% CO2) shortly after the exposure. The experiments established that survival of hypoxic Jurkat and U937 cells exceeded that of air-equilibrated controls about twofold (P < .01). Conversely, saturation of the medium with oxygen prior to exposure decreased Jurkat cell survival about 1.5 times, P < .01. Attenuation of the cytotoxic effect under hypoxic conditions resembled a well-known effect of oxygen on cell killing by sparsely ionizing radiations and may be indicative of the similarity of underlying cell damage mechanisms.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.