Abstract
A detailed description of the Langmuir probe system on Mega Ampere Spherical Tokamak Upgrade is presented. The system features 850 tile-embedded probes and 40 bespoke electronic modules that each have the capability to drive and acquire data from up to 16 probes in a time-multiplexed manner. The system provides spatiotemporal-resolved measurements (1cm and ∼1ms, respectively) in the divertor region of ion saturation current, electron temperature, and floating potential. The standard interpretation of current-voltage (IV) characteristics is to apply a four-parameter fit, based on unmagnetized probe theory, which includes a linear model for the ion saturation region. To mitigate the effect of the magnetic field, analysis is restricted to the region of the IV characteristic, which is sensitive to only the tail of the electron energy distribution function.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.