Abstract
Overlay accuracy in step-and-repeat X-ray lithography is evaluated through MOS device fabrication using an X-ray stepper applied to four lithography levels. Though relatively good overlay accuracies of 0.15 µm (σ) between two levels are obtained, these values are not satisfactory for sub-half-micrometer ULSI fabrication. To improve overlay accuracy, error factors are investigated. It is found that overlay errors are strongly affected by mask pattern placement errors. The standard deviation of mask errors is as high as 0.1 µm. These errors are introduced by e-beam writing errors and pattern displacement caused by stress relief of absorber and membrane layers in the etching process. The influence of these error factors on pattern placement accuracy is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.