Abstract
Taking deformation of the main arch under dead load as the arch alignment control target, the overall cable force and pre-camber of multi-rib arch were calculated by zero-order optimization method. According to the installation sequences of arch segments, taking deviation of cable tower, cables in one-time tensioning method and the section stress of arch chords as constraint conditions, the cable force and pre-camber for every segment were calculated by iterative method. This method is applied to the erection of a 400m steel truss arch bridge with three ribs, the calculated values of cable force are anastomosed with the measured ones, and the precision of arch alignment is high.
Published Version
Talk to us