Abstract
To meet NRC (US Nuclear Regulatory Commission) regulatory requirements for post-accident power monitoring at a commercial BWR (boiling-water reactor) plant, an out-of-core (ex-core) neutron-flux detector to measure reactor power was evaluated and installed. Several multigroup calculations and measurements, which predicted sufficient flux leakage outside the vessel, are described in detail. Since BWR plants currently use only in-core detectors for flux monitoring, the ex-core detector installation required backfit inside the reactor shield wall. The modification of removable shield blocks was readily accomplished during a scheduled outage. It is concluded that some BWR plants can economically utilize excore flux monitors to meet regulatory requirements.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.