Abstract
BackgroundPosterior chamber intraocular lens (IOL) dislocation is a common complication of cataract surgery. Dislocated IOLs often require surgical intervention due to the potentially severe risks of leaving this condition untreated. If a patient with extremely low corneal endothelial cell density (ECD) presents with IOL dislocation, the surgeon faces a crucial dilemma of choosing the most optimal surgical treatment option. We sought to investigate the efficacy and safety of retropupillary iris claw intraocular lens (R-IOL) implantation in patients with IOL dislocation and extremely low (< 1000 cells/mm2) ECD.MethodsWe retrospectively reviewed the medical records of nine patients (all men) whose pre-operative ECD was < 1000 cells/mm2 and who underwent R-IOL implantation due to intraocular subluxation or total dislocation into the vitreous cavity between 2014 and 2020. We evaluated corneal endothelial function and visual outcomes after surgery.ResultsNine patients were included in this study. The mean age at diagnosis was 64.89 ± 7.15 years (range 57–76 years), and the follow-up duration was 37.93 ± 23.72 months (range 18.07–89.07 months). No patients developed bullous keratopathy during follow-up. Compared to the initial ECD, corneal thickness (CT), coefficient variation of cell area (CV) and percentage of hexagonal cells (HEX), there was no statistically significant decrease in the ECD, CV, and HEX at last follow-up (P = 0.944, 0.778, 0.445, 0.443). There was significant improvement in the mean uncorrected distance visual acuity (UDVA) at the last follow-up (average 0.13 logMAR, 20/27 Snellen) compared to the pre-operative mean UDVA (average 1.09 logMAR, 20/250 Snellen) (P < 0.01).ConclusionsR-IOL implantation did not result in a statistically significant decline in corneal endothelial function in patients with preoperatively low ECD, and it significantly improved the mean UDVA postoperatively. R-IOL implantation appears to be a safe and effective treatment modality for intraocular lens dislocation in patients with low ECD (< 1000 cells/mm²); however, long-term follow-up studies are warranted to corroborate these findings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.