Abstract

BackgroundTo compare the incidence of complications and constructive effects of cranioplasty with polyetheretherketone (PEEK) and titanium mesh after decompressive craniectomy, and to further explore potential risk factors of postoperative and post-discharge complications.MethodsA retrospective study was conducted on 211 patients who underwent PEEK or titanium mesh cranioplasty in the Department of Neurosurgery of Zhujiang Hospital, Southern Medical University, between July 2017 and September 2021. Demographic data, imaging data, and postoperative complications were recorded and statistically analyzed. Long-term effects and satisfaction degree were evaluated based on following-up telephone survey. Univariate and multivariate logistic regression models were used to analyze risk factors of postoperative and post-discharge complications of PEEK and titanium cranioplasty.ResultsThe total postoperative complication rates of the PEEK and titanium mesh groups were 38.7 and 51.4% (p = 0.063), and post-discharge complication rates were 34.7 and 36.0% (p = 0.703), respectively. The incidence of pneumocephalus during hospitalization (33.3% vs. 6.6%, p < 0.001) and epidural effusion in the titanium mesh group were significantly higher than that in the PEEK group (18.0 vs. 6.6%, p = 0.011). Patients in PEEK group were less likely to occur subcutaneous effusion after discharge than in TI group (2.0 vs. 10.5%, p = 0.013). Multivariate logistic regression analysis revealed a history of ventriculoperitoneal shunt (VPS) before CP was an independent risk factor for postoperative overall complications (p = 0.023). Either superficial (p < 0.001) or intracranial infection (p = 0.001) was a risk factor for implant failure. Depressed skull defects (p = 0.024) and cranioplasty with titanium cranioplasty (p < 0.001) were associated with increased incidence of early pneumocephalus.ConclusionThere were no differences in overall postoperative and post-discharge complication rates between the titanium mesh and PEEK. A history of VPS before cranioplasty was an independent risk factor for postoperative overall complications, and infection was a risk factor for implant failure. Finally, depression skull defects and titanium mesh implants increased the incidence of postoperative pneumocephalus. Our results aim to promote a better understanding of PEEK and titanium cranioplasty and to help both clinicians and patients make better choices on implant materials.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.