Abstract

The sensitivity of interior noise that the passengers perceive is comparatively high in the train, and structure-borne and air-borne types of noises come into the train. In this paper, to analyze contributions of these noise sources operational transfer path analysis(OTPA) is used. OTPA has some advantages of executing the contribution rates of several sources simultaneously, and in this work, 29 points are measured while running. Transfer functions between reference measurement points and response measurement points are calculated by the singular value decomposition(SVD) and Principal component analysis(PCA) method, and the frequency characteristics of the noise source are successfully derived. Also the interior noise is predicted and compared with measurement data to show the reliability.