Abstract

The concept of generating an oscillatory electroosmotic flux inside the porous particle to enhance the intra-particle mass transport was presented and a new kind of electrochromatography carried out in a five-compartment electrolyzer were developed. The adsorbent was packed in the central compartment, while the neighboring compartments were used as the elution compartments and the electrode compartments, respectively. Chromatographic separations of human serum albumin on Blue Sepharose Fast Flow, bovine serum albumin (BSA) on DEAE–Sepharose Fast Flow, and BSA on hydroxyapatite were carried out, respectively. The adsorption isotherms were shown to be independent of electric field, while the increase in the electric field strength resulted in a linear increase in the magnitude of electroosmotic flux and the improvement of the breakthrough behavior in all cases. The experiment results have demonstrated the effectiveness of the oscillatory electroosmosis in enhancing intra- and inter-particle mass transport and its high potential to large-scale chromatography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.