Abstract

A dark count rate in InP-based single photon counting avalanche photodiodes is a limiting factor to their efficacy. The temperature dependence of the dark count rate was studied to understand its origin in In0.53Ga0.47As∕In0.52Al0.48As separate-absorption-charge-multiplication avalanche photodiodes. The dark count rate was observed to be a very weak function of temperature in the range from 77Kto300K. Various mechanisms for dark count generation were considered. Simulations of band-to-band tunneling in the In0.52Al0.48As multiplication layer were found to agree well with the experimental temperature dependence of dark count rate at various excess biases. To reduce tunneling-induced dark counts, a suitable design change to the detector structure is proposed.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call