Abstract
Coagulation and adsorption are two widely recommended pretreatments to ultrafiltration (UF) membranes. Optimal concentrations of ferric chloride and powdered activated carbon (PAC) are reducing membrane fouling and increasing the retention of the organic matter. Intuitive pretreatment may result in either increased fouling or in low retention of organic matter. In addition, the inside-out capillaries might become partially plugged by the formed flocs. The understanding of the fouling mechanisms in inside-out capillaries is therefore a challenging and much practically needed task. We investigated the fouling using an unique setup with separate measurements of flux and retention of organic matter in five segments of a 1.5-m long multibore capillary. The high coagulant doses resulted in average 90% humic acid retention and in severe fouling. The use of powdered activated carbon at higher pH also contributed to severe increases in membrane resistance. As the filtration progressed, the dead-end part of the capillary (far from the feed) gradually became clogged with flocs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.