This study has determined the optimal ratios of heat conductance of a cold-side heat exchanger to that of a hot-side heat exchanger when the heating load and the coefficient of performance (COP) of the irreversible air heat pump cycles are taken as the optimization objectives. Both the optimum distributions of heat conductance corresponding to the maximum heating load and the maximum COP are less than 0.5 for the fixed total heat exchanger inventory. The influences of the heat reservoir temperature ratio, the total heat exchanger inventory, and the efficiencies of the compressor and expander on the optimum distribution of heat conductance and the maximum heating load and the maximum COP are analysed and shown by numerical examples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.