Abstract

Partially superconducting direct-drive wind turbine generators with high-temperature superconducting excitation winding enable an increase of the rated unit power, higher efficiency, and a high, adjustable power factor. The high excitation ampere-turns allow for iron topologies that differ from conventional permanent magnet-excited generators. This study compares four different iron topologies for 7,mathrm{MW} rated power and 8.33 rpm with a slotted stator or stator air gap winding regarding technical key characteristics and economic aspects. The generator designs are numerically optimized based on 2D finite element simulations. Maximum efficiency and the most lightweight designs are obtained with the stator air gap winding, whereas all-iron topologies prove advantageous regarding the trade-off between small active mass and high-temperature superconductor material consumption. The costs of the cryogenic cooling system and of the full converter are both found to be less than 15% for a wide range of generator designs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.