Abstract

To research the magnetic field and mechanical characteristics of the permanent magnet governor, the static magnetic field of the sector permanent magnet is analyzed by the molecular current method in the permanent magnet governor. The magnetic flux distribution is acquired at any spatial position. Comparing the analytical value with the simulation value, the results show that they are basically consistent. Based on the analytical formula, the influence of the radial position, radial length, thickness, and pole number on the magnetic induction intensity of the permanent magnet governor is studied. Thus, it provides the theoretical reference for the structural optimized design. At the same time, a test bench was set up to measure the magnetic induction intensity. The calculation and experimental results show that the magnetic induction strength of the permanent magnet is increased by 27.5%, the axial component of the air gap flux density is increased by 14.3%, and the permanent magnet material is reduced by 7.84%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.