Abstract
The primary focus telescope has the advantages of a large field of view and less loss of light energy, and plays an important role in the field of time-domain survey. The 1-meter large field-of-view telescope of Nanjing University uses the primary focus optical system. The 6k × 6k CCD is located at the primary focal point in the optical path. The CCD will have a large amount of heat during the working process, which will affect the telescope's imaging quality. According to the requirements of the imaging quality of the NTU 1-meter telescope optical system, the difference between the temperature of the CCD housing and the ambient temperature needs to be controlled within 1 ℃. Therefore, the paper proposes a temperature control scheme for thermal insulation materials, and optimizes the performance of the temperature control scheme. The temperature control accuracy of this solution is within 0.6 ℃.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: DEStech Transactions on Engineering and Technology Research
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.