Abstract

The treatment of wheat samples was optimized before the determination of phytic acid by high-performance liquid chromatography with refractive index detection. Drying by lyophilization and oven drying were studied; drying by lyophilization gave better results, confirming that this step is critical in preventing significant loss of analyte. In the extraction step, washing of the residue and collection of this water before retention of the phytates in the NH2 Sep-Pak cartridge were important. The retention of phytates in the NH2 Sep-Pak cartridge and elimination of the HCI did not produce significant loss (P = 0.05) in the phytic acid content of the sample. Recoveries of phytic acid averaged 91%, which is a substantial improvement with respect to values reported by others using this methodology.