Abstract

A welding transformer represents a vital part of a resistance spot welding (RSW) system. Therefore, it is essential to ensure minimum copper loss in the windings. This paper describes a single-objective optimization procedure, which includes searching for the minimum copper loss in RSW transformer windings in regard to the dimensions of the primary and secondary windings. Copper loss in windings is obtained using an improved analytical method of successive approximation, which enables the calculation of current density distribution in coils with rectangular conductors. Finally, the calculated optimum windings' dimensions are further used in a parametric numerical model with the finite element method to confirm the reduction of copper loss.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.