Abstract
High-frequency (HF) transformers used in pulse-width-modulated power converters conduct periodic non-sinusoidal HF currents, which give rise to additional winding losses caused by harmonics. This study presents expressions for winding power losses in a two-winding transformer with periodic non-sinusoidal primary and secondary current waveforms for flyback converters operating in the continuous conduction mode (CCM). Dowell's equation, which takes into account both the skin and proximity effects, is used to determine the primary and secondary winding resistances as functions of frequency. Fourier series of the primary and secondary current waveforms and the winding resistances are used to determine the winding power losses at harmonic frequencies. The harmonic primary and secondary winding loss factors FRph and FRsh are introduced for CCM operation. The theory is illustrated by performance evaluation of the transformer in a flyback converter in CCM over the entire range of converter operation. Power losses in the primary and secondary transformer windings are illustrated as functions of the output power and the DC input voltage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.