Abstract
Surface plasmon resonance (SPR) sensors based on metal gratings have received much attention for designing compact and portable biosensors. In this paper, we systematically optimize SPR sensors based on sinusoidal and rectangular gratings to improve the performance of this kind of sensors. A parameter (FOM*) is defined to evaluate the sensor performance, which combines the sensitivity, FWHM, and depth of the SPR absorption peak. We find that grating period of 560 nm is suitable to locate the SPR peaks in the optimal response range of silicon detectors and ensures high sensitivity. For sinusoidal gratings, the highest FOM* of 99.25 is achieved at grating depth of 15 nm. The highest FOM* for rectangular grating with continuous metal film is 123.70 when grating depth and duty cycle are 12 nm and 0.3, respectively. With grating depth of 24 nm and duty cycle of 0.8, the highest FOM* of 25.23 is obtained for rectangular grating with discontinuous metal film. These optimization results can be directly used to improve the detection limit of compact SPR sensors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.