Abstract

Immunoassays play a pivotal role in detecting and quantifying specific proteins within biological samples. However, its sensitivity and turnaround time are constrained by the passive diffusion of target molecules towards the sensors. ACET (Alternating Current Electrothermal) enhanced reaction emerges as a solution to overcome this limitation. The ACET-enhanced biosensor works by inducing vortices through electrothermal force, which stirs the analyte within the microchannel and promotes a reaction process. In this study, a comprehensive two-dimensional finite element study is conducted to optimize the binding efficiency and detection time of an ACET-enhanced biosensor without external pumping. Optimal geometries for interdigitated electrodes are estimated to achieve significant improvements in terms of probe utilization and enhancement factor. The study’s findings demonstrate enhancement factors of 3.21, 2.15, and 3.09 along with 71.22%, 75.80%, and 57.52% normalized binding for C-reactive protein (CRP), immunoglobulin (IgG), and SARS-CoV-2, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.