Abstract
A high power (20MW) and CW millimeter wave (mm-wave) injection is planned for Electron Cyclotron Heating and Current Drive (EC H&CD) in ITER. An optimization of the mm-wave system for the ITER EC H&CD Equatorial Launcher (EL) is performed. The optimization of the system is aimed to obtain the maximum transmission efficiency on the condition that 1.8MW injection per waveguide, ∼20cm in beam radius at the resonance layer and narrow opening of the Blanket Shielding Module (BSM). The transmission efficiency of 99.1% from the end of the waveguide inside the launcher to the output of the BSM is achieved.The mm-wave propagation with high order modes is also calculated by using an experimentally obtained high power mm-wave beam pattern that includes 95%HE11, 0.6%LP11, 0.2%LP02 and 4.2% other higher order modes. The analysis predicts the 1–2% additional loss will be induced by the high order modes.