Abstract

Cardiovascular diseases are the leading cause of death and disability in most countries of the world. Therefore, the crucial task of pharmacy and medicine is the creation of drugs for the treatment of these pathologies. As a result of pharmacological studies, the optimal ratio of L-arginine with thiotriazoline – 4:1 was found. It was proposed to use modern, high-precision method of high-performance liquid chromatography (HPLC) to determine the active substances in the dosage form. Objective. The purpose of our study is to develop a method for the simultaneous determination of L-arginine and thiotriazoline standardization in model mixture by high-performance liquid chromatography, in particular the selection of the mobile and stationary phase. Materials and methods . L-arginine (manufactured by Sigma-Aldrich, China), thiotriazoline (manufactured by the State Enterprise Chemical Reagents Plant of the Scientific and Technological Complex Institute of Single Crystals of the National Academy of Sciences of Ukraine) was used for the study. The studies were carried out using a modular BISCHOFF HPLC system (BISCHOFF Analysentechnik GmbH, Germany) with a Lambda 1010 spectrophotometric detector. Results: At first, the determination was carried out on the reverse phase, with L-arginine practically not retained (coming out at the “dead volume”), and the use of cyanated phase did not significantly affect the retention of L-arginine. Further, the retention time of L-arginine increased slightly under ion-pair chromatography on the reversed phase, in determining and using the eluent with tetrabutylammonium. The most acceptable result was obtained by using an ion buffer reagent acid buffer – 0.05 % solution of trifluoroacetic acid. Conclusion. Thus, according to the obtained results, we believe that the use of an acid buffer – 0.05 % solution of trifluoroacetic acid is one of the promising ways for the simultaneous determination of L-arginine with thiotriazoline in the model mixture along with the ion-pair reagent. In the future, we are going to use this technique for the standardization of a combined drug which includes L-arginine and thiotriazoline, in solid and liquid dosage forms.

Highlights

  • The purpose of our study is to develop a method for the simultaneous determination of L-arginine and thiotriazoline standardization in model mixture by high-performance liquid chromatography, in particular the selection of the mobile and stationary phase

  • The studies were carried out using a modular BISCHOFF highperformance liquid chromatography (HPLC) system (BISCHOFF Analysentechnik GmbH, Germany) with a Lambda 1010 spectrophotometric detector

  • According to the obtained results, we believe that the use of an acid buffer – 0.05 % solution of trifluoroacetic acid is one of the promising ways for the simultaneous determination of L-arginine with thiotriazoline in the model mixture along with the ion-pair reagent

Read more

Summary

Materials and methods

Water; 0.05 % aqueous solution of trifluoroacetic acid; Bu4NHSO4 3.4 g/l in water; Bu4NHSO4 3.4 g/l, Sl.No Column. Hypersil ODS-C18-5u Bu4NHSO4 3.4 g/l, 0.05% aqueous solution of trifluoroacetic acid. А: L-arginine, Т: thiotriazoline; TR: peak retention time of analyte. Aqueous solutions with a concentration of 0.04 mg/ml of L-arginine and thiotriazoline. Double peaks near dead column volume Solutions in the eluent with a concentration of 0.04 mg/ml L-arginine and thiotriazoline. Solutions in an eluent with 1:1 concentrations of L-arginine and thiotriazoline (0.4 mg/ml). 0.02 M Na2HPO4 in water; Bu4NHSO4 3.4 g/l, 0.05 % solution of trifluoroacetic acid in water were used as the eluents. The concentrations of active substances were studied in the range from 0.04 mg/ml to 0.4 mg/ml

Results
Conclusion
Results and discussion
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call