Abstract
Heat sinks are frequently used in the cooling of electrical and electronics devices If the heat sink have very close fin spacing, it increases the surface area but reduces the heat transfer coefficient. On the other hand, if heat sink has wide fin spacing, it reduces the surface area but increases the heat transfer coefficient. Therefore, there is need to optimize the fin spacing that enhanced the heat transfer from the heat sink. A properly selected heat sink may reduced the operating temperature and reduce the risk of failure of components. A steady state natural convective heat transfer from aluminum plate fin heat sink was examined experimentally. The length and thickness of fin was kept constant while height were varied from 5mm to 25mm and spacing varied between 5.5mm to 17mm.After experimentation, it was observed that fin spacing plays important role than any other geometrical parameters. Response surface methodology is used for optimization of fin spacing. It is observed that optimum fin spacing of heat sink is 8.28mm.The error analysis is done with the help of ANN and flow visualization were done using CFD
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Engineering and Advanced Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.