Abstract

In order to reduce the influence of temperature fluctuation on heat treatment of regenerative forging reheating furnace, a scheme of improving traditional cascade PID controller to fuzzy PID controller was proposed in this paper. Taking the actual PID parameters of reheating furnace in forging workshop of a steel plant as reference object, the feasibility of the scheme is simulated by using MATLAB/SIMULINK. The results show that: 1) The control effect of fuzzy PID control is better than that of PID control in overshoot and adjusting time when the gain coefficient is perturbed 30%; 2) The dynamic performance of the system does not change significantly when the time constant is perturbed 20%; 3) The fuzzy PID shows better stability when the lag time is perturbed 20%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.