Abstract

Two methods are proposed for microinstruction addressing in interpreting a control algorithm by a compositional microprogram control unit (CMCU). The method of refined addressing allows one to uniquely identify outputs of operational linear chains (OLCs) using a minimal number of address bits. The method of optimal addressing makes it possible to represent classes of pseudoequivalent OLCs using a minimal number of generalized intervals of the code space. The proposed methods are illustrated by examples. Both methods make it possible to reduce the number of look-up table (LUT) elements in a CMCU logic circuit in comparison with its base structure. In the majority of cases, the clock period decreases with decreasing the amount of hardware