Abstract

The usage of renewable energies, including geothermal energy, is expanding rapidly worldwide. The low efficiency of geothermal cycles has consistently highlighted the importance of recovering heat loss for these cycles. This paper proposes a combined power generation cycle (single flash geothermal cycle with trans-critical CO2 cycle) and simulates in the EES (Engineering Equation Solver) software. The results show that the design parameters of the proposed system are significantly improved compared to the BASIC single flash cycle. Then, the proposed approach is optimized using the genetic algorithm and the Nelder-Mead Simplex method. Separator pressure, steam turbine output pressure, and CO2 turbine inlet pressure are three assumed variable parameters, and exergy efficiency is the target parameter. In the default operating mode, the system exergy efficiency was 32%, increasing to 39% using the genetic algorithm and 37% using the Nelder-Mead method.