Abstract

In the present study, a natural circulation two phase closed thermosyphon flat plate solar water heater has been investigated theoretically under the actual field conditions of Cairo, Egypt. Also, the heater design parameters are optimized by means of the author’s simulation program that was verified experimentally in a previous paper. These parameters include the ratio of storage tank volume to collector area, storage tank dimensions ratios and height between the heater storage tank and collector. The computational results indicate that the storage tank volume to collector area ratio and the storage tank dimensions ratios have significant effects on the heater performance, while the height between the heater tank and collector has little effect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.