Abstract

In this paper, SHE based on Newton–Raphson algorithm is used for open-loop control of flying capacitor multilevel inverter. Without measuring current and capacitor voltages, as well as not using any controller and voltage feedback, proposed control strategy generates accurate switching angles, capable of balancing flying capacitor voltage and eliminates lower order harmonics while considering load power factor variation. Efficiency and robustness of proposed algorithm are verified by simulation and experiments. Results show that proposed method does effectively eliminate specific low-order harmonics, and inverter output voltage is resulted in low total harmonic distortion with desired number of levels and balanced capacitor voltages.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.