Abstract

In this article, Newton–Raphson optimization-based selective harmonic elimination pulse width modulation is investigated for open-loop control of flying capacitor multilevel inverter. Proposed control strategy has allowed giving up current and voltage measurement instrumentations and sensors used in case of closed loop–based control. Proposed control strategy generates accurate switching angles, capable to balance flying capacitor voltage and eliminate lower order harmonics considering load power factor variation. Algorithm performances are verified by simulation and experiments, and obtained results prove that proposed technique does effectively eliminate specific harmonics and balance capacitor voltages while getting inverter output voltage with desired number of levels.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.