Abstract
AbstractIn this paper, a reduced switch count single‐phase hybrid multilevel inverter (MLI) is presented. Level generation unit (LGU) and polarity changing unit (PCU) are the two parts of the presented topology which are connected in series. Other advantages of the proposed topology include the reduced switch count, higher level generation with reduced sources and the possibility of higher‐level generation with lower component counts. A single unit produces an output voltage of 13 levels with the modulation techniques as selective harmonic elimination pulse width modulation (SHEPWM) to improve harmonics. The use of selective harmonic elimination (SHM) is made to improve harmonics. The logical generation unit carries a series connection of multiple switched dc voltage sources with half and full‐bridge configurations. The proposed topology is verified by a hardware bench setup as well as in simulations which are developed in Simulink/MATLAB® environment.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.