Abstract
Previous research has discussed tea drying machines with energy sources from PLN. Tea drying machines with refrigerant systems require large electrical energy costs. The electrical energy produced by a tea drying machine is proportional to its performance and cost. This research designed a 400 WP solar cell (PLTS) as a power supply for drying tea leaves. PLTS was combined with a PLN electricity source. Hybrid energy from PLTS and PLN was designed to maximize the use of electrical energy used by drying tea leaves. PLC and SCADA were used to monitor input current, output voltage, and output power. PLC and SCADA can optimize load requirements. When the solar radiation received by the solar panels was not optimal, PLN was able to back up load requirements. The average voltage produced by hybrid energy was 232.4 V. Hybrid energy was able to save power usage of 108.92 W or 12.8% of the load power requirements
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.