Abstract

Pleural fluid adenosine deaminase level can be applied to rapidly detect tuberculous pleural effusion. We aimed to establish a local diagnostic cut-off value for pleural fluid adenosine deaminase to identify patients with tuberculous pleural effusion, and optimise its utility. We retrospectively reviewed the medical records of consecutive adults with pleural fluid adenosine deaminase level measured by the Diazyme commercial kit (Diazyme Laboratories, San Diego [CA], United States) during 1 January to 31 December 2011 in a cluster of public hospitals in Hong Kong. We considered its level alongside early (within 2 weeks) findings in pleural fluid and pleural biopsy, with and without applying Light's criteria in multiple scenarios. For each scenario, we used the receiver operating characteristic curve to identify a diagnostic cut-off value for pleural fluid adenosine deaminase, and estimated its positive and negative predictive values. A total of 860 medical records were reviewed. Pleural effusion was caused by congestive heart failure, chronic renal failure, or hypoalbuminaemia caused by liver or kidney diseases in 246 (28.6%) patients, malignancy in 198 (23.0%), non-tuberculous infection in 168 (19.5%), tuberculous pleural effusion in 157 (18.3%), and miscellaneous causes in 91 (10.6%). All those with tuberculous pleural effusion had a pleural fluid adenosine deaminase level of ≤100 U/L. When analysis was restricted to 689 patients with pleural fluid adenosine deaminase level of ≤100 U/L and early negative findings for malignancy and non-tuberculous infection in pleural fluid, the positive predictive value was significantly increased and the negative predictive value non-significantly reduced. Using this approach, neither additionally restricting analysis to exudates by Light's criteria nor adding closed pleural biopsy would further enhance predictive values. As such, the diagnostic cut-off value for pleural fluid adenosine deaminase is 26.5 U/L, with a sensitivity of 87.3%, specificity of 93.2%, positive predictive value of 79.2%, negative predictive value of 96.1%, and accuracy of 91.9%. Sex, age, and co-morbidity did not significantly affect prediction of tuberculous pleural effusion using the cut-off value. We have established a diagnostic cut-off level for pleural fluid adenosine deaminase in the diagnosis of tuberculous pleural effusion by restricting analysis to a level of ≤100 U/L, and considering early pleural fluid findings for malignancy and non-tuberculous infection, but not Light's criteria.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call