Abstract

A dodecahedron non-orthogonal redundant IMU configuration was selected as model. To improve fusion accuracy, we proposed an effective calculation method for measurement errors based on the correlation between measurement errors and fusion errors. The method considered the difference between traditional data fusion vector’s projection and measurement results, and then made a conversion from projection error to measurement error. Combined with optimal weighted least square method, measurement error was used to generate an optimal weighted matrix, and this made data fusion errors minimum. Simulations also proved that the fusion result of this method is more accurate than the result of traditional method.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call