Abstract

AC voltage controllers are used as induction motor starters in fan or pump drives and the crane hoist drives. This paper presents a method of identifying the end of soft start of an AC voltage controller-fed induction motor (IM) drive based on the voltage across the nonconducting thyristor through a dynamic simulation of the whole drive system. A two point current minimization technique is adopted to operate the drive system at the required optimal voltage under all operating conditions. This minimizes the motor losses. Graphic modeling of the whole drive system is done in a modular format using Design Star and dynamic simulation is done using SABER. The dynamic simulation results of the whole drive system are supported with experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.