Abstract
A modified optical design for a synchrotron radiation (SR) soft X-ray scanning microscopy beamline at Hefei National Synchrotron Radiation laboratory (HESYRL) has been done. On the beamline the main component is a linear monochromator which consists of a diaphragm with a diameter of 7 µm and a condenser zone plate (CZP). The CZP is selected from among three condenser zone plates with different parameters for the following three overlapping wavelength ranges: 1.97-2.78 nm, 2.74-3.87 nm, and 3.84-5.44 nm. Estimating the flux losses from the pinhole source to the end spot for 2.3 nm, for example, a photon flux of 3.1 × 105 photons/s can be achieved at the end spot from a 150 mA current and a high brightness configuration at HESYRL.Parameters of three kinds of CZPs are presented as a compromise to a variety of requirements from the experimenters. In addition, the thickness of some CZP layers, such as polyimide and gold, are calculated to be optimal. Finally, the processing steps for CZP fabrication at HESYRL are described briefly.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.