The stripping of amorphous hydrogenated carbon films ( a-C:H) using an rf oxygen plasma has been monitored using the optical emission from electronically excited CO, H and O species in the visible region of the spectrum. The end point has been detected by monitoring the emission intensity of O reactive species (777.2 nm) and CO emission (483.5 nm) intensity of the etching product.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.